<?xml version="1.0"?>
<DeviceConfiguration xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" UniqueId="839ac833-5492-41fa-8fad-418acb24da08" Name="ИТП17" Version="1.0.0" Hash="390660640300380660350390350380310380340380330660650660360370320390610390340620330660340380630300">
  <Protocol Name="Modbus">
    <SupportedChannels>
      <Channels>Com</Channels>
    </SupportedChannels>
  </Protocol>
  <Nodes>
    <Node xsi:type="Catalog" Name="Настройки измерительного входа" TreeId="1" TreeParentId="0" UniqueId="107f7c13-9bec-42b2-9ca3-7d6ad4c52e01" IsVisble="true">
      <Options />
    </Node>
    <Node xsi:type="Catalog" Name="Настройки ВУ" TreeId="3" TreeParentId="0" UniqueId="7d080927-a369-44ad-b8d9-6dd0affb8ad1" IsVisble="true">
      <Options />
    </Node>
    <Node xsi:type="Catalog" Name="Настройка цвета" TreeId="4" TreeParentId="0" UniqueId="7155c554-b4d7-406b-b218-f520ebc52451" IsVisble="true">
      <Options />
    </Node>
    <Node xsi:type="Parameter" Name="Измеренное значение на входе (IN)" TreeId="17" TreeParentId="1" UniqueId="f7433faf-aba3-40df-bb81-271a766eeec3" IsOperative="false" IsVisible="true" IsReadOnly="true">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="ff510c0d-ac73-4a41-9289-19303e9ab635" Registry="1" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Тип датчика (in.t)" TreeId="20" TreeParentId="1" UniqueId="cdd00b94-3de7-4cd5-98e9-66330a6d469a" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="38" Name="Ток 4..20 мА" />
        <Values>
          <EnumValue Id="38" Name="Ток 4..20 мА" />
          <EnumValue Id="1" Name="ТСМ (Cu50)" />
          <EnumValue Id="2" Name="ТСМ (Cu100)" />
          <EnumValue Id="3" Name="ТСМ (Cu500)" />
          <EnumValue Id="4" Name="ТСМ (Cu1000)" />
          <EnumValue Id="5" Name="ТСМ(50М)" />
          <EnumValue Id="6" Name="ТСМ(100М)" />
          <EnumValue Id="7" Name="ТСМ(500М)" />
          <EnumValue Id="8" Name="ТСМ(1000М)" />
          <EnumValue Id="9" Name="ТСП(Pt50)" />
          <EnumValue Id="10" Name="ТСП(Pt100)" />
          <EnumValue Id="11" Name="ТСП(Pt500)" />
          <EnumValue Id="12" Name="ТСП(Pt1000)" />
          <EnumValue Id="13" Name="ТСП(50П)" />
          <EnumValue Id="14" Name="ТСП(100П)" />
          <EnumValue Id="15" Name="ТСП(500П)" />
          <EnumValue Id="16" Name="ТСП(1000П)" />
          <EnumValue Id="17" Name="ТСН(100Н)" />
          <EnumValue Id="18" Name="ТСН(500Н)" />
          <EnumValue Id="19" Name="ТСН(1000Н)" />
          <EnumValue Id="20" Name="ТХК(L)" />
          <EnumValue Id="21" Name="ТХА(K)" />
          <EnumValue Id="22" Name="ТЖК(J)" />
          <EnumValue Id="23" Name="ТНН(N)" />
          <EnumValue Id="24" Name="ТМК(T)" />
          <EnumValue Id="25" Name="ТПП(S)" />
          <EnumValue Id="26" Name="ТПП(R)" />
          <EnumValue Id="27" Name="ТПР(B)" />
          <EnumValue Id="28" Name="ТВР(A-1)" />
          <EnumValue Id="29" Name="ТВР(A-2)" />
          <EnumValue Id="30" Name="ТВР(A-3)" />
          <EnumValue Id="31" Name="Typ.L (DIN 43710)" />
          <EnumValue Id="32" Name="Пирометр РК-15" />
          <EnumValue Id="33" Name="Пирометр РК-20" />
          <EnumValue Id="34" Name="Пирометр РС-20" />
          <EnumValue Id="35" Name="Пирометр РС-25" />
          <EnumValue Id="36" Name="Ток 0..5 мА" />
          <EnumValue Id="37" Name="Ток 0..20 мА" />
          <EnumValue Id="39" Name="Напряжение 2..10 В" />
          <EnumValue Id="40" Name="Напряжение 0..10 В" />
          <EnumValue Id="41" Name="Напряжение -50..50 мВ" />
          <EnumValue Id="42" Name="Напряжение 0..1 В" />
          <EnumValue Id="0" Name="OFF" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="532c497f-803a-41ea-a5f7-8573f90101db" Registry="3" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Постоянная времени фильтра (td)" TreeId="22" TreeParentId="1" UniqueId="9ffd47ee-49d8-4337-aa4b-011cb912e09f" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Uinteger</ValueType>
      <DefaultValue xsi:type="xsd:unsignedInt">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfUInt32" Name="RangeValidator">
        <Min>0</Min>
        <Max>10</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="ad098e7d-24e0-4cb8-b2f6-59a7f6c3462d" Registry="4" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Функция извлечения квадратного корня из значения входа (Sqrt)" TreeId="21" TreeParentId="1" UniqueId="e87557b8-b99a-4b8b-b5cd-ebf0f0a4f9fb" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="OFF" />
        <Values>
          <EnumValue Id="0" Name="OFF" />
          <EnumValue Id="1" Name="ON" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="764e331d-da69-43dd-9b6c-0b43fb6f4018" Registry="5" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Нижнее значение физического параметра (di.Lo)" TreeId="23" TreeParentId="1" UniqueId="fc09cc4e-b826-4363-b553-5d92da2236eb" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="e3e06f44-2ab4-446d-8607-b60bfc41f80b" Registry="6" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Верхнее значение физ. параметра (di.Hi)" TreeId="24" TreeParentId="1" UniqueId="8f7641e7-3d6d-4420-86f4-3ddff730a371" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">100</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="a8d74c3c-f74b-44de-98b7-17333edd8499" Registry="8" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Положение десятичной точки (dP.t)" TreeId="18" TreeParentId="1" UniqueId="00b80dd2-628b-4236-bd15-87e22bb3c409" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="1" Name="1" />
        <Values>
          <EnumValue Id="1" Name="1" />
          <EnumValue Id="0" Name="0" />
          <EnumValue Id="2" Name="2" />
          <EnumValue Id="3" Name="3" />
          <EnumValue Id="4" Name="auto" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="526a0d11-d8b5-4e80-8841-58544993cfb8" Registry="10" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="2х / 3х проводная схема изм. терморезистора (2u3u)" TreeId="11" TreeParentId="1" UniqueId="40ea3a3d-bd2d-4847-b832-131bf887e0d4" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="1" Name="3х проводная" />
        <Values>
          <EnumValue Id="1" Name="3х проводная" />
          <EnumValue Id="0" Name="2х проводная" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="b4c0e9e7-fe74-4b05-b2a3-06b37f910ac7" Registry="11" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Коррекция сдвига измеренного на входе значения (Сorr)" TreeId="12" TreeParentId="1" UniqueId="542998e2-b7db-4c3f-8f28-25aa9c9c7372" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="e84c269a-f047-443d-bbb8-e4730edbaf00" Registry="12" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Тип логики компаратора (Cnt)" TreeId="25" TreeParentId="3" UniqueId="61b4804b-25db-4b38-8b5c-90b7c568482e" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="2" Name="U" />
        <Values>
          <EnumValue Id="2" Name="U" />
          <EnumValue Id="1" Name="П" />
          <EnumValue Id="3" Name="HEAT" />
          <EnumValue Id="4" Name="COOL" />
          <EnumValue Id="0" Name="OFF" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="5731177b-82b5-4659-85b5-caa4d9cad58c" Registry="257" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Нижняя уставка компаратора (SP.Lo)" TreeId="26" TreeParentId="3" UniqueId="ecdc2653-ea8e-4ab8-aae7-630b059f0a29" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="5347fa00-e91a-472c-82bb-5d83a9348362" Registry="258" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Верхняя уставка компаратора (SP.Hi)" TreeId="27" TreeParentId="3" UniqueId="b09805b7-787e-44f1-9156-b197f48300c2" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">30</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="7f337bc6-c954-4d49-ac45-e610993f7ef7" Registry="260" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Гистерезис ВУ (A.HYS)" TreeId="28" TreeParentId="3" UniqueId="82585cc2-9268-4463-9de8-3b4885c6a659" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>0</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="cee4edc1-9539-4aea-a54b-ecbdd37f1f7a" Registry="262" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Состояние ВУ при отказе и откл. логике (out.E)" TreeId="29" TreeParentId="3" UniqueId="23fdef25-75ff-4a42-ae92-6c2c4a2f74e9" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="OFF" />
        <Values>
          <EnumValue Id="0" Name="OFF" />
          <EnumValue Id="1" Name="ON" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="60203082-bcd9-40b3-8f3b-aa4dd65a6604" Registry="264" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Мигание при включенном выходе (d.Fnc)" TreeId="30" TreeParentId="3" UniqueId="343cd5ec-a76f-4cb9-8205-812be9112564" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="OFF" />
        <Values>
          <EnumValue Id="0" Name="OFF" />
          <EnumValue Id="1" Name="ON" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="37878035-42a0-467a-8dfe-e9f1e692dfed" Registry="265" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Порог смены цвета с COL.D на COL.1 (Zon.1)" TreeId="31" TreeParentId="4" UniqueId="fc1075f1-6bc1-4ec3-b53a-5221f8f7fe99" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="eb40f907-c90b-4267-9ccc-3dbfe3ed52e5" Registry="513" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Порог смены цвета на COL.2 (Zon.2)" TreeId="35" TreeParentId="4" UniqueId="1ebdb046-77a8-48bb-aa65-7920f10aed94" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">50</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="52dbe055-256c-454c-8f48-b7bbed3097db" Registry="515" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Порог смены цвета на COL.3 (Zon.3)" TreeId="34" TreeParentId="4" UniqueId="65e39a22-f527-44c9-a8af-7e42b75afdff" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">80</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="43e80b91-224d-469a-82fc-c462021155b2" Registry="517" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Порог смены цвета на COL.4 (Zon.4)" TreeId="33" TreeParentId="4" UniqueId="95e02c33-3c60-44fc-9b48-60d4e858a2fb" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">100</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="cdfb6d7c-4587-4a7a-bcd1-2b37dcd21a5b" Registry="519" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Порог смены цвета c COL.4 на COL.D (Zon.5)" TreeId="32" TreeParentId="4" UniqueId="19cb2490-d337-4d7e-96b3-692273255245" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:decimal">100</DefaultValue>
      <Validator xsi:type="RangeValidatorOfDecimal" Name="RangeValidator">
        <Min>-1999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="3478d710-e019-40d7-a963-78f18603239b" Registry="521" Length="2" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Цвет зоны 1 (COL.1)" TreeId="42" TreeParentId="4" UniqueId="c1ca63a4-6114-43ec-b104-92269ab36353" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="Зеленый" />
        <Values>
          <EnumValue Id="0" Name="Зеленый" />
          <EnumValue Id="1" Name="Красный" />
          <EnumValue Id="2" Name="Желтый" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="03a3e2c4-f291-4af3-9355-6b9bad368385" Registry="523" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Цвет зоны 2 (COL.2)" TreeId="40" TreeParentId="4" UniqueId="2c2124d6-ea08-4d49-9e26-7dd45b68a3be" IsOperative="true" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="Зеленый" />
        <Values>
          <EnumValue Id="2" Name="Желтый" />
          <EnumValue Id="0" Name="Зеленый" />
          <EnumValue Id="1" Name="Красный" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="25daf9aa-3646-4aa9-9f43-473c7873d5cb" Registry="524" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Цвет зоны 3 (COL.3)" TreeId="39" TreeParentId="4" UniqueId="69355f99-6f03-460b-9a8a-070a8e8cce96" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="1" Name="Красный" />
        <Values>
          <EnumValue Id="1" Name="Красный" />
          <EnumValue Id="0" Name="Зеленый" />
          <EnumValue Id="2" Name="Желтый" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="f066f670-d4ed-4bf2-95df-d5ef75fb4c0f" Registry="525" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Цвет зоны 4 (COL.4)" TreeId="38" TreeParentId="4" UniqueId="37556f33-12cd-4438-bde5-37f7ff6c941b" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="1" Name="Красный" />
        <Values>
          <EnumValue Id="1" Name="Красный" />
          <EnumValue Id="0" Name="Зеленый" />
          <EnumValue Id="2" Name="Желтый" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="bc87e605-8a4c-4970-a2d6-c27429b6dd24" Registry="526" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Цвет индикации вне цветовых зон (COL.D)" TreeId="37" TreeParentId="4" UniqueId="e466ac8d-82c3-425a-8da7-7f981febc15b" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="Зеленый" />
        <Values>
          <EnumValue Id="0" Name="Зеленый" />
          <EnumValue Id="1" Name="Красный" />
          <EnumValue Id="2" Name="Желтый" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="1b1d92fe-f3bd-4f44-99a0-ac9cca0e025e" Registry="527" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Catalog" Name="Сервисное меню" TreeId="43" TreeParentId="0" UniqueId="87b4986a-5016-4e53-8799-0014f2a5d9de" IsVisble="true">
      <Options />
    </Node>
    <Node xsi:type="Parameter" Name="Название прибора (Dev.t)" TreeId="44" TreeParentId="43" UniqueId="82830227-4ee9-4f88-a5c9-137ddd0129d7" IsOperative="false" IsVisible="true" IsReadOnly="true" DesiredView="">
      <Options>
        <NodeOption xsi:type="DeviceInfoOption" />
        <NodeOption xsi:type="AutoDiscoverDeviceOption" />
        <NodeOption xsi:type="OnlineCheckOption" />
      </Options>
      <ValueType>String</ValueType>
      <DefaultValue xsi:type="xsd:string">ITP-17</DefaultValue>
      <Validator xsi:type="StringLengthValidator" Name="StringLengthValidator" MaxLength="6" />
      <Communication xsi:type="ModbusCommunication" Id="034f45f7-08eb-4a2d-bceb-cfb941d4dd3c" Registry="4097" Length="3" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Версия ПО (Ver.F)" TreeId="45" TreeParentId="43" UniqueId="26139924-bf8e-467d-b872-1e3302151b38" IsOperative="false" IsVisible="true" IsReadOnly="true">
      <Options>
        <NodeOption xsi:type="DeviceInfoOption" />
        <NodeOption xsi:type="VersionInfoOption" />
      </Options>
      <ValueType>String</ValueType>
      <DefaultValue xsi:type="xsd:string">V1.08</DefaultValue>
      <Validator xsi:type="StringLengthValidator" Name="StringLengthValidator" MaxLength="6" />
      <Communication xsi:type="ModbusCommunication" Id="80ac59e9-a4e2-4e47-8c6c-b9d6bd5b033c" Registry="4103" Length="3" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Использование ДХС (CJS.E)" TreeId="46" TreeParentId="43" UniqueId="65f95df8-ac33-4a43-89eb-8bcdf8410bf4" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="1" Name="ON" />
        <Values>
          <EnumValue Id="1" Name="ON" />
          <EnumValue Id="0" Name="OFF" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="9818e527-4430-4072-a36e-738acc486f89" Registry="4109" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Сброс на заводские настройки (d.Rst)" TreeId="47" TreeParentId="43" UniqueId="5395896b-98fd-442b-b754-7a14260b2d75" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="OFF" />
        <Values>
          <EnumValue Id="0" Name="OFF" />
          <EnumValue Id="1" Name="Сброс" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="a6e88bb0-65c7-41bc-b33b-3fa0f05d62c7" Registry="4110" Length="1" IsLittleEndian="false" IsLittleEndianWords="false">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
  </Nodes>
  <Services />
</DeviceConfiguration>