<?xml version="1.0"?>
<DeviceConfiguration xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" UniqueId="99412cc1-929b-451a-9100-9a3afbd7540a" Name="УЗС1" Version="1.0.0" Hash="330390380610630340340340630370370360620380380380340660370620390340640640610330320310660340330360">
  <Protocol Name="Modbus">
    <SupportedChannels>
      <Channels>Com</Channels>
    </SupportedChannels>
  </Protocol>
  <Nodes>
    <Node xsi:type="Catalog" Name="Оперативные параметры" TreeId="1" TreeParentId="0" UniqueId="d5363156-62c3-44b0-8795-c4da6062a637" IsVisble="true">
      <Options />
    </Node>
    <Node xsi:type="Parameter" Name="Тип прибора (DEVICE)" TreeId="4" TreeParentId="1" UniqueId="1f09e70b-c1ae-46c4-b974-1772da3224e6" IsOperative="true" IsVisible="true" IsReadOnly="true" DesiredView="">
      <Options>
        <NodeOption xsi:type="OnlineCheckOption" />
        <NodeOption xsi:type="DeviceInfoOption" />
        <NodeOption xsi:type="AutoDiscoverDeviceOption" />
      </Options>
      <ValueType>String</ValueType>
      <DefaultValue xsi:type="xsd:string">UZS1.USB</DefaultValue>
      <Validator xsi:type="StringLengthValidator" Name="StringLengthValidator" MaxLength="8" />
      <Communication xsi:type="ModbusCommunication" Id="0b7e0c44-370e-4b50-865f-8f2024b2b9fc" Registry="4096" Length="4" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Версия встраиваемого ПО (VERSION)" TreeId="5" TreeParentId="1" UniqueId="fdacedfd-45e9-4b5a-a657-dd610b3f07ac" IsOperative="true" IsVisible="true" IsReadOnly="true" DesiredView="">
      <Options>
        <NodeOption xsi:type="VersionInfoOption" />
        <NodeOption xsi:type="DeviceInfoOption" />
      </Options>
      <ValueType>String</ValueType>
      <DefaultValue xsi:type="xsd:string">VER 3.04</DefaultValue>
      <Validator xsi:type="StringLengthValidator" Name="StringLengthValidator" MaxLength="8" />
      <Communication xsi:type="ModbusCommunication" Id="951b83dc-ad7b-4cd2-b09e-37befbbc56de" Registry="4100" Length="4" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Статус прибора (битовая маска) (STATUS)" TreeId="6" TreeParentId="1" UniqueId="d58bea6f-eb48-4e63-9c5e-f5d5d58159b3" IsOperative="true" IsVisible="true" IsReadOnly="true" DesiredView="">
      <Options>
        <NodeOption xsi:type="VersionInfoOption" />
      </Options>
      <ValueType>Uinteger</ValueType>
      <DefaultValue xsi:type="xsd:unsignedInt">1</DefaultValue>
      <Validator xsi:type="RangeValidatorOfUInt32" Name="RangeValidator">
        <Min>0</Min>
        <Max>65535</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="ba2cbb9a-4b50-45f5-a6a4-b086d2b78e55" Registry="4104" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Измеренная величина на входе (FUN1)" TreeId="7" TreeParentId="1" UniqueId="c29a6c58-1774-4e8d-9d46-04d6c2809266" IsOperative="true" IsVisible="true" IsReadOnly="true" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>-9999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="95e7baed-0a40-4b42-8629-2e425e750e01" Registry="4109" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Выходная мощность на выходе (OUT.P)" TreeId="8" TreeParentId="1" UniqueId="480258c5-4bf9-4e48-bb87-eafd216370cf" IsOperative="true" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>0</Min>
        <Max>100</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="56684fcd-ad98-4685-ada3-89537bca02e8" Registry="4119" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Режим работы прибора (Ctrl)" TreeId="9" TreeParentId="1" UniqueId="573af799-fd1f-40f7-97b9-e814bd91f3e0" IsOperative="true" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="1" Name="AUTO" />
        <Values>
          <EnumValue Id="1" Name="AUTO" />
          <EnumValue Id="2" Name="MANUAL" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="92712959-9584-4ef5-8f50-48115a5e46bd" Registry="4121" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Удаленная перезагрузка прибора (RESET)" TreeId="10" TreeParentId="1" UniqueId="98e97440-c8be-4477-a561-7f340603f2ca" IsOperative="true" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Integer</ValueType>
      <DefaultValue xsi:type="xsd:int">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfInt32" Name="RangeValidator">
        <Min>0</Min>
        <Max>1</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="07f6194a-c476-42db-9da0-0ec69b28bd5d" Registry="4122" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Catalog" Name="Основные параметры" TreeId="11" TreeParentId="0" UniqueId="bbd77662-deab-44d9-9cb8-211fddf03a93" IsVisble="true">
      <Options />
    </Node>
    <Node xsi:type="Parameter" Name="Измеренная величина на входе (после функции) (FUN1)" TreeId="12" TreeParentId="11" UniqueId="fc84fd44-d11f-4d03-b14a-956bacadfd26" IsOperative="false" IsVisible="true" IsReadOnly="true" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>-9999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="7c5c3fd0-6059-4117-afd1-b005ca41dbf6" Registry="0" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Входная величина на входе (до функции) (PV1)" TreeId="13" TreeParentId="11" UniqueId="13559cd0-f662-4058-ac3a-78e72e2a0dfa" IsOperative="false" IsVisible="true" IsReadOnly="true" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>-9999</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="627c407f-8ff8-4c2e-8f76-488a1a5bcaa1" Registry="2" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand xsi:nil="true" />
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Тип датчика на входе (Type)" TreeId="14" TreeParentId="11" UniqueId="22380a61-ccf3-4e95-9738-39a282922868" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="OFF" />
        <Values>
          <EnumValue Id="0" Name="OFF" />
          <EnumValue Id="38" Name="Ток 0..5 мА" />
          <EnumValue Id="39" Name="Ток 0..20 мА" />
          <EnumValue Id="40" Name="Ток 4..20 мА" />
          <EnumValue Id="41" Name="Напряжение -50..50 мВ" />
          <EnumValue Id="42" Name="Напряжение 0..1 В" />
          <EnumValue Id="43" Name="Напряжение 0..10 В" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="4bd0ce45-faf4-4c10-9ed2-a57aeb91ee83" Registry="4" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Постоянная времени фильтра (Fil.t)" TreeId="15" TreeParentId="11" UniqueId="800d8348-3e04-4ec5-9815-80bd2c812408" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Uinteger</ValueType>
      <DefaultValue xsi:type="xsd:unsignedInt">10</DefaultValue>
      <Validator xsi:type="RangeValidatorOfUInt32" Name="RangeValidator">
        <Min>0</Min>
        <Max>999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="b699c751-e7b8-40b2-ba06-856fa16cc593" Registry="7" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Положение десятичной точки (Dpt)" TreeId="16" TreeParentId="11" UniqueId="ac13691e-2a96-4db5-8222-fa8218685d11" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="0" />
        <Values>
          <EnumValue Id="0" Name="0" />
          <EnumValue Id="1" Name="1" />
          <EnumValue Id="2" Name="2" />
          <EnumValue Id="3" Name="3" />
          <EnumValue Id="4" Name="AUTO" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="6eb29d19-e252-44b0-81d3-07b0f2ef600f" Registry="8" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Значение параметра корректировки входа (Corr)" TreeId="17" TreeParentId="11" UniqueId="a9e689b3-35d0-4b4d-93cf-1a8a50a033af" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>-50</Min>
        <Max>50</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="69f452c6-fe79-40e2-81d0-d588778f739e" Registry="698" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Способ перевода прибора в ручной режим (Man.S)" TreeId="18" TreeParentId="11" UniqueId="247705ec-efa8-44a3-b5e5-4f037cd2232f" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="С лицевой панели" />
        <Values>
          <EnumValue Id="0" Name="С лицевой панели" />
          <EnumValue Id="1" Name="С внешней кнопки" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="31f5e2c3-6036-4167-b4d4-de20eebfd561" Registry="694" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Логика работы выходного устройства (LOG.A)" TreeId="19" TreeParentId="11" UniqueId="ce28c47b-74df-4ca9-82e5-1c9f04b7904c" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="6" Name="Прямо пропорционально" />
        <Values>
          <EnumValue Id="6" Name="Прямо пропорционально" />
          <EnumValue Id="7" Name="Обратно пропорционально" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="4a1101b5-fdaa-4b02-8880-a29ed820272c" Registry="608" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Логика работы дискретного выхода (LOG.D)" TreeId="20" TreeParentId="11" UniqueId="7d992caa-481b-409d-add7-35c075e6fbea" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="При смене режима работы" />
        <Values>
          <EnumValue Id="1" Name="При смене режима работы" />
          <EnumValue Id="0" Name="При аварии" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="bcd2d4bc-6baf-40e6-a839-00f5278ba89a" Registry="697" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Текущее значение ВУ в процентах (OUT.P)" TreeId="21" TreeParentId="11" UniqueId="06e6c8d0-a086-4d73-85ec-70544c265ef2" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>0</Min>
        <Max>100</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="2f116e05-e2ec-4c1d-abb9-f88e5d7d654e" Registry="689" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Значение ВУ при переходе в ручной режим (OUT.M)" TreeId="22" TreeParentId="11" UniqueId="5888474e-be8c-4911-bd40-05c6568ab711" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>-1</Min>
        <Max>100</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="3ab8be62-bb21-459a-969d-b1e9633729cc" Registry="692" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Безопасное состояние выхода в режима Ошибка (Err.A)" TreeId="23" TreeParentId="11" UniqueId="7000605d-70bc-4858-96c1-10ba73f7dfd9" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Float</ValueType>
      <DefaultValue xsi:type="xsd:float">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfSingle" Name="RangeValidator">
        <Min>0</Min>
        <Max>20</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="e2e95838-2f07-4157-8e3b-804f655c95b0" Registry="695" Length="2" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Catalog" Name="Меню скрытых параметров (SCRT)" TreeId="24" TreeParentId="0" UniqueId="1d8cd810-9b4d-4d6b-9333-38b62a1a4628" IsVisble="true">
      <Options />
    </Node>
    <Node xsi:type="Parameter" Name="Пароль доступа к меню (PASS)" TreeId="25" TreeParentId="24" UniqueId="70952794-717c-4e73-9d3e-cfd68052ee9b" IsOperative="false" IsVisible="true" IsReadOnly="false">
      <Options />
      <ValueType>Integer</ValueType>
      <DefaultValue xsi:type="xsd:int">0</DefaultValue>
      <Validator xsi:type="RangeValidatorOfInt32" Name="RangeValidator">
        <Min>0</Min>
        <Max>9999</Max>
      </Validator>
      <Communication xsi:type="ModbusCommunication" Id="2b8c6df5-cb4c-4c59-acb5-c185ac3b92cd" Registry="2048" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Защита от редактирований значений переменных (Prt.E) " TreeId="26" TreeParentId="24" UniqueId="3bd5fbd6-40ad-48a6-ac81-bcea285ceda9" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="OFF" />
        <Values>
          <EnumValue Id="0" Name="OFF" />
          <EnumValue Id="1" Name="SETT" />
          <EnumValue Id="2" Name="ALL" />
          <EnumValue Id="3" Name="HIDE" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="a06440eb-2246-42b1-9e7d-3c29f5f6bc71" Registry="2049" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
    <Node xsi:type="Parameter" Name="Включение атрибутов скрытых параметров (Atr.E)" TreeId="27" TreeParentId="24" UniqueId="54dfc159-d739-4df2-b766-c6732b191aa7" IsOperative="false" IsVisible="true" IsReadOnly="false" DesiredView="">
      <Options />
      <ValueType>Enumeration</ValueType>
      <DefaultValue xsi:type="Enumeration">
        <DefaultValue Id="0" Name="OFF" />
        <Values>
          <EnumValue Id="0" Name="OFF" />
          <EnumValue Id="1" Name="ON" />
          <EnumValue Id="2" Name="EDIT" />
        </Values>
      </DefaultValue>
      <Communication xsi:type="ModbusCommunication" Id="c8571a96-fe60-4c94-ab34-9a7e2b850855" Registry="2050" Length="1" IsLittleEndian="false" IsLittleEndianWords="true">
        <ModbusReadCommand>ReadHoldingRegisters</ModbusReadCommand>
        <ModbusWriteCommand>WriteMultipleRegisters</ModbusWriteCommand>
      </Communication>
    </Node>
  </Nodes>
  <Services />
</DeviceConfiguration>